• UPS module-HP-T
UPS module-HP-T

Share to

UPS module-HP-T

Power range: 10kVA-80kVA

Are you still deciding? Get samples first, Contact us!

View similar products

Products Tag

  • Product Description
  • Product Introduction

    Three in and three out

    Power range: 10kVA-80kVA

    Applicable industries: Medical equipment, computer equipment, precision instrument equipment, communication network management centers, banks/securities settlement centers, highway lighting/billing, automated production lines and their control systems.

    Product features

    1. Intelligent digital technology

    The inverter and PFC of the UPS adopt advanced digital control technology, with an input power factor of ≥0.99 and very low input current harmonics, effectively enhancing product performance and system reliability, and achieving higher power density integration and miniaturization.

    2. Friendly human-machine interface

    It adopts a 7-inch touch screen design, clearly displaying the operation status, load status, mains power status, battery power supply status, etc. of the UPS on the panel, allowing users to keep track of the changes in the UPS power supply quality and application environment at any time.

    3. Compatible with generator input

    The input voltage and frequency range are wide, providing clean, safe and stable power supply for the load.

    4. Output isolation transformer

    External input and output transforme

    Operation method TURE ON-LINE UPS
      Input Phase Single-phase  L+N+GN/Three-phase (A+B+C)+N+GND
    Voltage Phase voltage (220±15%)VAC
    Line voltage (380±15%)VAC
    Frequency range (50±5%) Hz
    Output Rated capacity 5KVA 6KVA 7.5KVA 8KVA 10KVA
    Rated voltage Single-phase 220VAC
    Voltage accuracy (220±1%) VAC
    Output frequency (50 ±0.5%) Hz (Battery status)
    Output waveform Pure sine wave
    Power factor 0.8
    Wave distortion <3% (Linear full load)
    Overload capacity 105%~125%: maintain for 10 min then switch to bypass; 125%~130%: maintain for 1 min then switch to bypass; >150%: switch to bypass immediately and return to UPS supply automatically after overload is removed.
    Degree of average flow unbalance (parallel operation only) ≤1%
    Switching time 0ms

    Efficiency(AC→AC)

      >85%
    DCsource DC voltage 110V/220V
    Protection Overload protection Switch to bypass power supply
    Overheat protection Switch to bypass power supply when above 85°C
    Short circuit protection Limit the current and switch off the UPS, the circuit breaker trips off automatically
    Overvoltage protection Switched to bypass when the UPS output is overvoltage
    Undervoltage protection Shut down the UPS when the battery is undervoltage
    Display LED indication Mains power indicator, inverter indicator, bypass indicator, low battery indicator, overload indicator and fault indicator
    LCD display Bypass, input, output, battery voltage; bypass, input and output frequency; load percentage; UPS functioning status, historical event etc.
    Alarm Buzzer Mains power interruption, low battery, overloaded output, UPS fault, etc.
    Interface RS232/RS485 interface Standard equipped with a RS232 and a RS485, with multiple built-in protocols which can be configured.
    Ambient parameter Operating temperature (0~ 40)℃
    Relative humidity <95% (non-condensing)
    Noise <55dB (1-meter distance)
    Mechanical Specifications Dimension (mm) W×D×H 482*440*264
    Weight (kg) 25

    Built-in input and output transformer 

    Operation method TURE ON-LINE UPS
      Input Phase Single-phase    L+N+GND/Three-phase (A+B+C)+N+GND Three-phase (A+B+C)+N+GND
    Voltage Phase voltage (220±15%)VAC
    Line voltage (380± 15%)VAC
    Line voltage (380±15%)VAC
    Frequency range (50±5%) Hz
    Output Rated capacity 1-3KVA 4-6KVA 7.5-8KVA 10-15KVA
    Rated voltage Single-phase 220VAC
    Voltage accuracy (220±1%) VAC
    Output frequency (50 ±0.5%) Hz (Battery status)
    Output waveform Pure sine wave
    Power factor 0.8
    Wave distortion <3% (Linear full load)
    Overload capacity 105%~125%: maintain for 10 min then switch to bypass; 125%~130%: maintain for 1 min then switch to bypass; >150%: switch to bypass immediately and return to UPS supply automatically after overload is removed.
    Degree of average flow unbalance (parallel operation only) ≤1%
    Switching time 0ms

    Efficiency(AC→AC)

      >85%
    DCsource DC voltage 110V/220V
    Protection Overload protection Switch to bypass power supply
    Overheat protection Switch to bypass power supply when above 85°C
    Short circuit protection Limit the current and switch off the UPS, the circuit breaker trips off automatically
    Overvoltage protection Switched to bypass when the UPS output is overvoltage
    Undervoltage protection Shut down the UPS when the battery is undervoltage
    Display LED indication Mains power indicator, inverter indicator, bypass indicator, low battery indicator, overload indicator and fault indicator
    LCD display Bypass, input, output, battery voltage; bypass, input and output frequency; load percentage; UPS functioning status, historical event etc.
    Alarm Buzzer Mains power interruption, low battery, overloaded output, UPS fault, etc.
    Interface RS232/RS485 interface Standard equipped with a RS232 and a RS485, with multiple built-in protocols which can be configured.
    Ambient parameter Operating temperature (0~ 40)℃
    Relative humidity <95% (non-condensing)
    Noise <55dB (1-meter distance)
    Mechanical Specifications Dimension (mm) W×D×H 422*461*176 422*419*352 440*470*704 440*470*704
    Weight (kg) 61 87 160 160

UPS module-HP-T


Power range: 10kVA-80kVA