Three in and three out
Power range: 10kVA-80kVA
Applicable industries: Medical equipment, computer equipment, precision instrument equipment, communication network management centers, banks/securities settlement centers, highway lighting/billing, automated production lines and their control systems.
Product features
1. Intelligent digital technology
The inverter and PFC of the UPS adopt advanced digital control technology, with an input power factor of ≥0.99 and very low input current harmonics, effectively enhancing product performance and system reliability, and achieving higher power density integration and miniaturization.
2. Friendly human-machine interface
It adopts a 7-inch touch screen design, clearly displaying the operation status, load status, mains power status, battery power supply status, etc. of the UPS on the panel, allowing users to keep track of the changes in the UPS power supply quality and application environment at any time.
3. Compatible with generator input
The input voltage and frequency range are wide, providing clean, safe and stable power supply for the load.
4. Output isolation transformer
External input and output transforme
Operation method TURE ON-LINE UPS Input Phase Single-phase L+N+GN/Three-phase (A+B+C)+N+GND Voltage Phase voltage (220±15%)VAC
Line voltage (380±15%)VACFrequency range (50±5%) Hz Output Rated capacity 5KVA 6KVA 7.5KVA 8KVA 10KVA Rated voltage Single-phase 220VAC Voltage accuracy (220±1%) VAC Output frequency (50 ±0.5%) Hz (Battery status) Output waveform Pure sine wave Power factor 0.8 Wave distortion <3% (Linear full load) Overload capacity 105%~125%: maintain for 10 min then switch to bypass; 125%~130%: maintain for 1 min then switch to bypass; >150%: switch to bypass immediately and return to UPS supply automatically after overload is removed. Degree of average flow unbalance (parallel operation only) ≤1% Switching time 0ms Efficiency(AC→AC)
>85% DCsource DC voltage 110V/220V Protection Overload protection Switch to bypass power supply Overheat protection Switch to bypass power supply when above 85°C Short circuit protection Limit the current and switch off the UPS, the circuit breaker trips off automatically Overvoltage protection Switched to bypass when the UPS output is overvoltage Undervoltage protection Shut down the UPS when the battery is undervoltage Display LED indication Mains power indicator, inverter indicator, bypass indicator, low battery indicator, overload indicator and fault indicator LCD display Bypass, input, output, battery voltage; bypass, input and output frequency; load percentage; UPS functioning status, historical event etc. Alarm Buzzer Mains power interruption, low battery, overloaded output, UPS fault, etc. Interface RS232/RS485 interface Standard equipped with a RS232 and a RS485, with multiple built-in protocols which can be configured. Ambient parameter Operating temperature (0~ 40)℃ Relative humidity <95% (non-condensing) Noise <55dB (1-meter distance) Mechanical Specifications Dimension (mm) W×D×H 482*440*264 Weight (kg) 25 Built-in input and output transformer
Operation method TURE ON-LINE UPS Input Phase Single-phase L+N+GND/Three-phase (A+B+C)+N+GND Three-phase (A+B+C)+N+GND Voltage Phase voltage (220±15%)VAC
Line voltage (380± 15%)VACLine voltage (380±15%)VAC Frequency range (50±5%) Hz Output Rated capacity 1-3KVA 4-6KVA 7.5-8KVA 10-15KVA Rated voltage Single-phase 220VAC Voltage accuracy (220±1%) VAC Output frequency (50 ±0.5%) Hz (Battery status) Output waveform Pure sine wave Power factor 0.8 Wave distortion <3% (Linear full load) Overload capacity 105%~125%: maintain for 10 min then switch to bypass; 125%~130%: maintain for 1 min then switch to bypass; >150%: switch to bypass immediately and return to UPS supply automatically after overload is removed. Degree of average flow unbalance (parallel operation only) ≤1% Switching time 0ms Efficiency(AC→AC)
>85% DCsource DC voltage 110V/220V Protection Overload protection Switch to bypass power supply Overheat protection Switch to bypass power supply when above 85°C Short circuit protection Limit the current and switch off the UPS, the circuit breaker trips off automatically Overvoltage protection Switched to bypass when the UPS output is overvoltage Undervoltage protection Shut down the UPS when the battery is undervoltage Display LED indication Mains power indicator, inverter indicator, bypass indicator, low battery indicator, overload indicator and fault indicator LCD display Bypass, input, output, battery voltage; bypass, input and output frequency; load percentage; UPS functioning status, historical event etc. Alarm Buzzer Mains power interruption, low battery, overloaded output, UPS fault, etc. Interface RS232/RS485 interface Standard equipped with a RS232 and a RS485, with multiple built-in protocols which can be configured. Ambient parameter Operating temperature (0~ 40)℃ Relative humidity <95% (non-condensing) Noise <55dB (1-meter distance) Mechanical Specifications Dimension (mm) W×D×H 422*461*176 422*419*352 440*470*704 440*470*704 Weight (kg) 61 87 160 160